The Rocker 400 vacuum pump oil free system is an advanced, piston-driven laboratory suction device engineered for vacuum filtration, suspended solid testing, and analytical sample concentration across Saudi Arabia. Operating on a standard 220V electrical supply, this unit provides a free air displacement flow rate of 34 L/min at 50Hz (37 L/min at 60Hz) and achieves an ultimate vacuum capability down to 99 mbar abs. Sourcing an authentic rocker vacuum pump 400 ensures clean, hydrocarbon-free negative pressure, protecting sensitive analytical filter membranes from aerosol contamination. For institutional testing facilities, deploying the reliable rocker 400 pump guarantees consistent performance across high-volume sample queues.
Key Operational Advantages
Engineered to deliver clean, quiet, and dependable suction for benchtop applications, this rocker 400 oil free vacuum pump provides several verified performance benefits.
- Prote™ Overflow Protection Mechanism: Equipped with an integrated buoy float valve inside the moisture trap that immediately blocks the suction intake if waste liquid overflows from the collection flask, safeguarding internal cylinders from liquid ingress.
- Maintenance-Free Piston Drive: The Rocker 400 vacuum pump oil free design operates entirely without lubricating oil, eliminating fluid top-ups, routine oil changes, and hydrocarbon exhaust mist throughout the service life of this Rocker 400 oil free laboratory vacuum pump.
- High Airflow Displacement: Generates up to 34 L/min of air displacement at 50Hz, accelerating filtration cycles across single-funnel stations and multi-branch vacuum manifolds.
- Integrated Suction Regulation: Features a built-in dial vacuum gauge and precision needle regulator, allowing technicians using the Rocker 400 vacuum pump oil free unit to monitor and calibrate vacuum levels for delicate membrane filtration.
- Intake Air Filtration: Contains an inlet filter cartridge that captures airborne dust particles and moisture aerosols before they reach the valve head, extending mechanical service life.
- Thermal Overload Protection: Includes an automatic thermal cutout switch that deactivates the motor if internal temperatures spike and re-engages once the unit cools to safe operating levels.
- Quiet Benchtop Operation: The rocker 400 pump operates at an unobtrusive sound level of 52 dB, maintaining a quiet working atmosphere in research and clinical facilities.
- Certified Manufacturing Quality: Built in accordance with CE, CSA, RoHS, and IP30 standards, backed by a comprehensive manufacturer 2-year warranty.
Technical Specifications
Review the comprehensive mechanical, electrical, and performance parameters for this specialized rocker 400 vacuum pump KSA research and testing benches utilize.
| Manufacturer / Brand | Rocker Scientific |
|---|---|
| Model Designation | Rocker 400 |
| Part Number / Ordering Code | 167400-22 (220V, 50Hz) / 167400-11 (110V, 60Hz) |
| Pump Mechanism | Piston Type, 100% Oil-Free |
| Maximum Vacuum Capability | 99 mbar abs. (Approx. -680 mmHg / -90.6 kPa) |
| Max. Flow Rate (50Hz) | 34 L/min @ 220V, 50Hz |
| Max. Flow Rate (60Hz) | 37 L/min @ 220V, 60Hz |
| Operating Voltage & Frequency | 220V AC, 50/60Hz |
| Power Consumption | 80W (1/6 HP) @ 50Hz | 100W (1/6 HP) @ 60Hz |
| Current Draw | 0.4A @ 220V, 50Hz | 1.0A @ 110V, 60Hz |
| Noise Level | 52 dB |
| Hose Barb Connection | ID8 (8 mm Inner Diameter Tubing) |
| Net Weight | 5.2 kg |
| Dimensions (L x W x H) | 31.0 cm x 14.0 cm x 20.0 cm |
| Integrated Safety Systems | Prote™ Overflow Protection, Thermal Cut-off Switch |
| Regulatory Certifications | CE Certified, CSA Recognized, RoHS Compliant, IP30 Protection |
| Manufacturer Warranty | 2-Year Factory Warranty |
Laboratory Applications Across Saudi Arabia
Deploying a genuine rocker 400 Saudi arabia laboratory pump satisfies rigorous quality protocols across scientific, medical, and environmental facilities.
- Suspended Solid (SS) Water Testing: Delivers continuous, stable suction for standard environmental water quality analysis in municipal testing laboratories across Riyadh, Jeddah, and the Eastern Province. Utilizing the dependable Rocker 400 vacuum pump oil free assembly ensures rapid particulate separation through glass fiber filter discs.
- Multi-Branch Vacuum Filtration Manifolds: Maintains steady negative pressure across 3-branch and 6-branch manifold systems utilized for microbial concentration and aqueous clarification when driven by the rocker vacuum pump 400.
- Microbiological & Bioburden Testing: Employed in pharmaceutical clean rooms and food quality testing benches for sterile membrane filtration of broth, process water, and raw liquid ingredients with the certified Rocker 400 oil free laboratory vacuum pump.
- Air Sampling & Particulate Analysis: Functions as a dependable negative pressure generator for drawing ambient aerosols and particulate matter onto analytical filter discs in industrial cities such as Jubail and Yanbu using the rugged rocker 400 pump.
- Solid Phase Extraction (SPE) & Solvent Clarification: Driven by the rocker 400 oil free vacuum pump, it accelerates analytical sample preparation without introducing volatile oil fumes that could disrupt sensitive chromatographs or spectrometers.
How to Use / Install
Follow standard operating protocols to set up and operate your Rocker 400 vacuum pump oil free unit efficiently.
- Benchtop Positioning: Place the unit on a flat, sturdy laboratory bench, ensuring at least 10 cm of clearance around the rear motor vents for convective cooling.
- Electrical Connection: Verify that the local power outlet matches the 220V rating and insert the grounded power cord into the receptacle to safely power your rocker 400 vacuum pump KSA setup.
- Attach Vacuum Hose: Firmly slide an ID8 (8 mm internal diameter) vacuum-rated silicone or reinforced PVC hose over the intake hose barb on the moisture trap.
- Connect Lab Glassware: Connect the opposite end of the hose to your filtering flask, vacuum manifold, or filtration assembly, ensuring all glassware is vacuum-rated.
- Power On and Regulate: Flip the power switch to the ON position. Adjust the needle regulator knob while reading the dial vacuum gauge to set your desired vacuum level on the Rocker 400 vacuum pump oil free system.
- Controlled Shutdown: When filtration concludes, release internal line vacuum via the regulator knob before turning off the pump motor to avoid back-siphoning.
Precautions & Maintenance Protocols
Adhering to correct maintenance protocols ensures long-term performance and extends the operating life of your rocker vacuum pump 400.
- Aqueous & Non-Corrosive Duty: This unit is engineered for ambient air and aqueous moisture filtration; never aspirate concentrated corrosive acids, halogen vapors, or flammable organic solvents directly through the pump head.
- Drain Moisture Trap Promptly: Inspect the moisture trap regularly during heavy filtration cycles and empty any accumulated condensate to keep the Prote™ float clear on your Rocker 400 vacuum pump oil free unit.
- Inspect Inlet Filter Element: Check the filter cartridge positioned behind the regulator regularly; replace the filter element if particulate discoloration or reduced airflow occurs on your rocker 400 pump.
- Maintain Unobstructed Exhaust: Keep the exhaust ports completely clear during operation to prevent back pressure buildup and ensure motor ventilation.
- Thermal Reset Clearance: If the thermal protection switch halts operation, turn the pump OFF and allow it to cool for 20 to 30 minutes in a well-ventilated area before restarting.
Why Choose ASKA Solution?
AskA Solution supplies verified laboratory equipment and scientific consumables backed by regional technical support across Saudi Arabia.
- Authentic Laboratory Hardware: We source original Rocker Scientific pumps and accessories directly to ensure genuine component durability and factory 2-year warranty protection.
- Regional Technical Support: Knowledgeable product consultation to assist laboratory personnel in matching vacuum parameters to their analytical filtration workflows.
- Dependable Procurement Coordination: Responsive quotation handling and dependable supply logistics for institutional, government, and commercial laboratories choosing the rocker 400 Saudi arabia solution.
FAQs
Find answers to common technical and operational questions regarding the Rocker 400 vacuum pump oil free platform.
- What makes the Rocker 400 vacuum pump oil free design advantageous for microbiology testing?
The pump uses a 100% oil-free piston mechanism that requires no lubricating oil. This eliminates exhaust oil mist entirely, preventing hydrocarbon contamination on sterile filtration membranes, culture media, and analytical samples. - How does the Prote™ overflow protection feature work?
The Prote™ mechanism consists of an internal buoy float valve housed in the intake moisture trap. If a collection flask overflows, the rising liquid causes the float to lift and seal the suction inlet instantly, preventing fluid from entering the valve head and damaging the piston. - What size vacuum tubing is compatible with the Rocker 400?
The pump features an ID8 hose barb connection, designed for flexible vacuum tubing with an internal diameter of 8 mm (5/16 inch). - Can the vacuum level be adjusted for sensitive membrane filters?
Yes, the unit comes standard with a dampening dial vacuum gauge and a precision needle regulator, allowing operators to fine-tune the suction pressure and prevent membrane rupture. - What warranty is provided with the Rocker 400 pump?
The Rocker 400 pump includes an official 2-year manufacturer warranty covering mechanical components and manufacturing integrity under standard laboratory operating conditions.