9-425mm Blue Screw PP Cap
Aska Solution is the premier scientific equipment supplier in Riyadh and Dammam. We provide an essential Polypropylene Screw Cap for demanding analytical applications daily. Consequently, our standard HPLC Vial Caps Pre Slit secure liquid integrity efficiently. Furthermore, technicians across Saudi Arabia trust our fast local delivery.
Features
This durable laboratory fastener offers tangible benefits for daily analytical operations.
- Multiple Injections: The cross-slit design reduces dangerous septa coring during sampling.
- Airtight Seal: High-quality Blue Screw Caps prevent the evaporation of volatile compounds.
- Broad Compatibility: A precision 9mm Screw Cap perfectly matches major analytical instruments.
- Temperature Range: The bonded septum remains stable under intense laboratory heat consistently.
- Universal Thread: The precise threading fits standard autosampler trays flawlessly.
Technical Specifications
Every single manufactured component meets rigorous industrial and international quality standards.
- Material Integrity: The Polypropylene Screw Cap resists aggressive laboratory chemicals continuously.
- Septum Quality: It features a bonded PTFE and white silicone barrier.
- Standard Sizing: The 9-425mm Blue Screw PP Cap fits exactly over two-milliliter vials.
- Packaging Standard: Items ship in airtight packs to prevent any cross-contamination.
- Color Coding: The bright blue color helps technicians identify specific solvent batches.
Data Table
Review the exact dimensional and material properties below.
| Specification | Detail |
|---|---|
| Product Name | 9-425mm Screw Cap with Pre-Slit Liner |
| Cap Material | Polypropylene (PP) |
| Cap Size / Thread | 9-425mm |
| Cap Color | Blue |
| Liner Material | White Silicone / Red PTFE |
| Temperature Range | -40°C to +200°C |
Applications
Chemists across Jeddah and Riyadh specify this hardware for critical tasks.
- Chromatography: These Blue Screw Caps prepare samples for High-Performance Liquid Chromatography.
- Pharmaceutical Quality: Chemists verify raw materials using reliable HPLC Vial Caps Pre Slit.
- Environmental Testing: Labs analyze soil pollutants and trace water contaminants accurately.
- Food Safety: Technicians detect trace additives within the local food industry.
- Clinical Research: Researchers utilize these specialized seals for sensitive biological samples.
How To Use
Follow these straightforward steps to achieve a perfect sample vial seal.
- Selection: Choose the appropriate 9mm Screw Cap based on your vial type.
- Preparation: Transfer your liquid sample into the glass container carefully.
- Alignment: Place the closure flat onto the glass thread surface firmly.
- Tightening: Twist the plastic closure until it feels completely snug.
- Final Loading: Place the sealed vial directly into your automated sampler unit.
Warning
Always observe safety protocols when handling pressurized chemical laboratory containers.
- Overtightening: Excessive force can distort the delicate septum and cause leaks.
- Pressure Limits: Exceeding thermal ratings can violently rupture the sealed glass container.
- Chemical Compatibility: Ensure your solvent does not dissolve the inner silicone layer.
- Chemical Hazards: Wear appropriate PPE according to standard OSHA laboratory safety guidelines.
- Fume Extraction: Always open volatile samples inside a certified chemical fume hood.
Precautions
Store and handle these consumables correctly to preserve their analytical integrity.
- Storage Conditions: Keep the plastic closures in their original sealed bag.
- Contamination Risk: Never touch the inner septum surface with your bare hands.
- Single Use: Discard closures after one use to prevent sample carryover completely.
- Visual Inspection: Discard any items showing visible dents or septum layer separation.
- Temperature Control: Store unused supplies in a cool, dry, and clean environment.
Frequently Asked Questions (FAQs)
1. What is the primary function of the 9-425mm Blue Screw PP Cap?
It securely seals vials for chromatography and prevents sample evaporation.
2. Can I use these closures for multiple needle injections?
Yes. The pre-slit silicone layer allows the needle to pierce safely.
3. Why use a bonded liner instead of a loose one?
A bonded liner prevents the septum from falling out during preparation.
4. How do I prevent septum distortion during capping?
Simply tighten the plastic thread until snug, avoiding excessive twisting force.
5. Do you ship these laboratory consumables to Jubail?
Yes. We maintain extensive local inventory for rapid deployment across Saudi Arabia.
Still have questions or need a custom solution? Contact our team today — we’re ready to help.










ahmadshahraz69 –
Top-tier 9-425mm pre-slit caps for chromatography vials. The bonded white silicone and red PTFE liner offers excellent chemical resistance and guarantees a clean, secure injection every single time
Shivnarine Chanderpaul –
Top-tier 9-425mm screw caps for HPLC vials. They fit perfectly, resist chemical wear, and ensure our automated samplers run flawlessly every single time.
Nicole Meratin –
Highly dependable screw caps for high-throughput testing. The pre-slit design is flawless, the chemical resistance is excellent, and they handle multiple injections smoothly without degrading.